04/26/2019 Firmware #5.414
- Firmware: Bug in MIDI CC Set Hammond XK solved (hopefully)
- Firmware: Sends rotary control via MIDI (NI B4 compatible)
04/25/2019 Firmware #5.412
- Firmware: Bug in Panel16 "Button Vibrato" routine fixed (erraneous V1..V3 LED behaviour on Drawbar Expander)
- File HX35_EditArrDescAdvanced.hx3 updated (erraneous Menu Enables)
03/08/2019 Firmware #5.411
- Firmware: Bug in LED driver fixed, Rotary LED was not blinking on Panel16 and MenuPanel
- Firmware: Removed obsolete factory reset procedure
- Editor: Bug in Licence Creation fixed (affects OEMs only)
02/05/2019 Firmware #5.410, Scan #19 (Fatar)
- Scan driver Fatar: Timing revised, eliminates "ghost" notes on some installations
- Firmware: Menu entries for equalizer enabled when Extended Licence not installed
02/05/2019 Firmware #5.409, DSP #01.15/11.15, Scan #18
- Scan driver Fatar/Scan61: Bug in local key transpose fixed
- DSP: Equalizer enabled without extended licence
- Firmware: Phasing Rotor also on B3 mode, Equalizer enabled without extended licence
- HX3.5 Editor: Added param #1396, limit generator model selection
02/05/2019 Firmware #5.408 BETA
- HX3.5 Editor: Deleted Binary Events buttons, will never be used
- Firmware: Bugfix Preset16 lower manual button handling
- Firmware: Added "Latching Preset Keys" mode (System Init param #1508) for Preset12-MPX (old) and Preset12-2
Note: "Latching Preset Keys" mode uses voice preset key #12 ("Cancel" key, Preset12 input pin 12) for
voice saving as on HX3 mk4. When using two drawbar sets per manual, set param
"2ndDB Select Voice Number" to 15 (Preset12-MPX) resp. 1 (Preset12-2). See
HX3.5 Mainboard Wiki
for details.
01/27/2019 Firmware #5.407
- HX3.5 Editor: Deleted Touch Button Remap table, will never be used
- HX3.5 Editor: Missing autorun.ini replaced
- Firmware: Bugfix Button/Switch Remap, improved Preset Button handling
- Firmware: Removed Separate Pedal menu item from standard organ configuration
01/27/2019 Firmware #5.406 BETA, DSP #01.14 (with GM voices) and #11.14 (no GM, but more reverb algorithms), Scan #17
- Firmware: Tube Amp Insert and Rotary Simulation Insert Tabs are now bypass tabs
(inverted function). Running config_xxx.ini will only update live preset. Existent
presets 1 to 15 must be adjusted manually (set tube amp and rotary sim bypass off to turn sim on)
- Firmware: Bugfix in Nord C1/C2 MIDI CC set (did not receive lower manual CCs)
- Firmware: Versatile CC set documentation added (see Manuals directory)
- Scan Driver for Scan16/61 #17: Fixed bug that caused all notes ON all the time
Important: Running config_xxx.ini will only update live preset to new bypass
tab functions. Existent presets 1 to 15 must be adjusted manually (set tube amp
and rotary sim bypass off to turn sim on). Alternatively, Finalize
board presets in HX3.5 Editors Update/Finalize window (all existent presets will
be overwritten).
01/09/2019 HX3.5 Editor 5.4051, DSP #01.14 (with GM voices) and #11.14 (no GM, but more reverb algorithms)
- HX3.5 Editor: Bugfix Taperings update, wrong filename
- DSP: Bugfix in USB library to prevent DSP stall using VMware Windows emulation on MacOS
- DSP: Extension board sustain pedal inputs separated for upper ("Bass" jack) and lower manual ("Main" jack),
former sostenuto input is now sustain pedal for lower manual. Sostenuto function
omitted.
12/12/2018 Firmware #5.405, DSP #01.13 (with GM voices) and #11.13 (no GM, but more reverb algorithms)
- DSP: Equalizer Bypass added
- Firmware: Softer percussion for H100 Mode
- Firmware: Preset16 Button "DoubleTap" feature (will recall GM voices, +16, blinking Preset16 LED) on standard organ installations may be turned off with param #1509
12/12/2018 Firmware #5.403 BETA, DSP #01.12 (with GM voices) and #11.12 (no GM, but more reverb algorithms)
- DSP: Fixed a bug that prevented SysEx block transfers
- DSP: Re-sorted DSP NRPNs
- Firmware: Generator mode on Parameter 1266 to retain compatibility with #5.3xx
- DSP: 3-Band Equalizer added with parametric mid control, available from
MenuPanel and HX3.5 Editor parameters "Volume Pots" resp. "Trim Pots". Equalizer
affects both Rotary simulation as well as Leslie (R) output on extension board.
Note: 3-Band EQ available for extended Licence only.
- Firmware: Generator Mode "knob" added. Will set waveset (sine distortion), key click
params, tonewheel count and note frequencies according to selected model.
- Firmware: Keying/Gating tabs (EG/H100) will not affect independant Generator Mode
- Firmware: Generator Mode "M3/M100" added
- Firmware #5.401: ADC scaling factor for MAG organs added (limited potentiometer range), should be at 120 for MAG organs and 100 for other
- Firmware #5.401: Fixed Equalizer parameter order
- Firmware #5.403: fixed Menu enables
Please update DSP to 01.12 or 11.12 first before attempting firmware or FPGA updates!
Click "Start DFU" in HX3.5 Editor's "Update/Finalize Panel" to start DFU Update.
Firmware #5.4 only works with DSP #01.12 resp. #11.12 and vice versa. See Update
Notes above!
Common firmware and EEPROM files for all products now contained
in HX3.5 Editor 5.4 ZIP from now on - no need to download UPDATE ZIPs
separately if not using SD Card for updates.
10/13/2018 Firmware 5.301, Scan Driver #17
- Scan Driver: Split will affect local keyboard only. Split will have no effect on MIDI input.
- Firmware: Bugfix, SysEx communication (i.e. HX3.5 Editor connection) fails on MIDI channels different from 1
Update Scan Driver if using MIDI input with masterkeyboards (will handle split
itself). If you want to retain previous split function (affects sound
generator), do not update Scan Driver or use #16 (enclosed).
09/19/2018 Firmware 5.300
- Firmware: Clavia Nord C1/C2 MIDI CC set #7
- Firmware: MIDI ProgramChange Send/Receive
- Firmware: MIDI Swell (Expression) Send, CC number same as in MIDI menu
- Firmware: Bank Select Send/Receive for Overall Presets
- Firmware: Faster integrator for MIDI Swell/Volume changes
- Firmware: Bugfixes 2nd Drawbar Set Select for DB9 MPX, Percussion Cancel
- HX3.5 Editor: Minor cosmetic changes, added DFU driver for Win XP in ZIP
Firmware 5.3 set to final status (no changes since last version 5.300 BETA).
Only "Firmware Update" (no EEPROM) necessary if updating from 5.105 and up.
KNOWN BUG: SysEx Communications will fail on MIDI Channels other than 1.
Therefore, HX3.5 Editor will no longer work with MIDI over USB connection.
Workaround: With HX3.5 MenuPanel, set MIDI Channel to 1 and store. In HX3.5
Editor, set parameter 1368 to 0 (= MIDI Channel 1).
09/19/2018 DSP Firmware HX35_5504-FW_0106.dfu, Firmware 5.202 BETA
- Firmware: Faster response to swell and volume changes via MIDI
- Firmware: Shortened menu list
- Firmware: Added Percussion/2nd Voice Level to menu
- Firmware: Added Envelope Drawbars for "EG Percussion" organ mode to menu
- DSP: Bugfix, Distorted "long release" GM sounds or with Damper/Sustain pedal on
- DSP: Bugfix, SysEx End recognition (GM sounds went off after SysEx transmission, i.e. HX3.5 Editor connected)
Only "Firmware Update" (no EEPROM) necessary if updating from 5.105 and up.
09/19/2018 Firmware #5.200, HX3.5 Editor #5.200
- HX3.5 Editor: Added function keys ESC, F1..F12 in Tab/DB Panel window for Preset/Voice recall #00..#12. USe SHIFT-ESC to SHIFT-F12 to read and refresh displayed parameters also. Use U/L/P/C keys to select Upper, Lower, Pedal or Common Presets.
- Firmware: Various small bug fixes, simplified Preset handling
- Firmware: New "Enable Preset Mask" parameter 1498 to enable/disable storing various param groups either to preset or to startup defaults (see parameter description in HX3.5 Editor)
09/19/2018 DSP Firmware HX35_5504-FW_0105.dfu and HX35_5504-FW_noGM_1105.dfu
- Added reverb to Extension board Leslie 11-pin and Output jacks
- Alternative DSP Reverb firmare noGM_11.05 available: No GM (Piano) voices, but more "large" Reverb Programs 0..9 instead of 0..3.
- List of reverb programs: 0: Off, 1: Short Room, 2: Room A, 3: Room B,
4: Small Hall A, 5: Small Hall B, 6: Large Hall A,
7: Large Hall B, 8: Short Plate, 9: Vocal Plate (Editor "Reverb Setup" Parameters 1145..1147)
DSP updates are included in the HX3.5 Editor ZIP.
See DSP Update Page for details.
09/20/2018 Scan Driver 5x.16 for Scan61-Inline and Scan16
- Added Scan Driver "scansr61.dat" for Scan61-Inline and Scan16 (single-contact keybeds)
- HX3.5 Editor: Added hint to run "config.ini" after firmware updates
- "config.ini" and "factory.ini" changed to sync Voices with Overall Presets, somewhat higher organ volume
For using the Scan61-Inline and Scan16 driver, just run "upd_sr61.ini" from
HX3.5 setup file menu (SD card) or update scan driver from HX3.5 Editor's
Update/Finalize window. "scansr61.dat" and "upd_sr61.ini" can be found in the
"UPDATE StdOrgan.ZIP".
09/19/2018 Firmware #5.105, HX3.5 Editor #5.105, Scan Driver 5x.16
- Firmware: Bugfix Preset/Live and Preset/Preset change
- Firmware: Will not forget presets and voices when updating
- Firmware: Bugfix "Split Mode not stored to Overall Presets"
- Scan Driver: Split mode handling improved
- Scan Driver: Bugfix non-working pedals on "Lower to Upper Split"
- HX3.5 Editor: Assignment Dropdown List Bugfix
- HX3.5 Editor: Changes for 16 KByte "preset.dat" file
For updates from #5.103 and below to #5.105 select "Firmware/EEPROM" and "Scan
Driver File" in HX3.5 Editor's Update/Finalize Window and Execute "config.ini"
from Editor. SD card updates will handle this automatically.
Hx3.5 will create a "preset.dat" file (button "Get & Save Preset Block" in
"Advanced" page) if connected by FTDI. This file contains all preset settings in
binary form. It may be uploaded by menu in Update/Finalize window or copied to
an SD card. If HX3.5 finds this file on a firmware update, it will be loaded
into preset memory.
Preset structure will not change in future, so this file may also be used as a backup.
09/12/2018 Firmware #5.104 BETA, HX3.5 Editor #5.104, Scan Driver 5x.15
- Known Bug: Preset/Preset change
- HX3.5 Editor: "Menu Enables" order fixed
- HX3.5 Editor: Added update entry "Firmware only" in Update/Finalize Window
- Firmware: Switching of H100/B2 Percussion fixed
- Firmware: "Sync Voices with Presets" enabled on UHL instruments
- Scan Driver: Bugfix MIDI channel assignment (was not able to receive on MIDI channels other than 1/2/3)
For updates to #5.104 select "Firmware/EEPROM" and "Scan Driver File" in HX3.5
Editor's Update/Finalize Window and Execute "config.ini" from Editor. SD card
updates will handle this automatically.
09/07/2018 Firmware #5.102, HX3.5 Editor #5.100, DSP #1.04
- HX3.5 Editor: New virtual organ panel with tabs and drawbars; should also work with older HX3.5 firmwares
- HX3.5 Editor: Will automatically start DreamDFU utility for DSP updates
- HX3.5 Editor: Added Backup support
- Firmware: Bugfix KeyB Duo MIDI CC set, Vibknob/MIDI to Panel16 translation, Perc menu display
- Firmware: Fail-save EEPROM file programming, unified firmware, "config.ini" support
- Firmware: Bugfix Percussion did not sound on preset to live change
- Firmware: Bugfix Rotary setting not memorized
- Firmware: Added Support for reading binary Preset and Voice setting blocks (OEM only)
- DSP: GM synth will no longer sound on channels out of organ channel range (1 to 3). Only update DSP if the GM synth should not sound on channels 4 to 16.
From firmware 5.1 and up, there is only one firmware common for all devices
(exception: MAG and UHL organs). Firmware is "personalized" to work on a
particular device by running a "config_xxx" INI script ("config_xxx.ini") from editor or by
using SD card after update is done.
If using an SD card for update, a script called "config.ini" is run
automatically after firmware update by "autorun.ini" (if present on card).
"config.ini" is simply a renamed "config_xxx.ini" file.
Please backup Licence Info before updating to #5.102! Unfortunately, older
firmwares had a data offset bug which did not retain licence information and
board defaults. When updating to #5.102, execute the "factory_xxx.ini" script
dedicated for your board application from HX3.5 Editor's Finalize window or
run "factory.ini" on SD card from HX3.5 Script Menu.
08/30/2018 Firmware #5.096, HX3.5 Editor #5.095
- Firmware: Bugfix "Bass Rotor won't stop completely"
- Firmware: Bugfix "KeyB (Duo) MIDI CC interpreter not working"
- HX3.5 Editor: Added Button "Create INI Script", creates INI setup file with all current parameters
- HX3.5 Editor: Added Button "Run INI Script", runs INI setup file from Editor similar to running from SD card
- Added INI Setup Scripts for manual full update via DisplayPanel menu (update.ini), forced EEPROM rewrite in case parameters are corrupted (eeprupd.ini),
and manual start DSP update in DFU mode, equivalent to HX3.5 Editor's "Start DFU" button (startdfu.ini)
08/25/2018 Firmware #5.093, HX3.5 Editor #5.09, DSP #01.03
- Firmware: Bugfix Update by USB MIDI
- Firmware: Added 8 separate Scanner Vibrato programs for 8 basic organ models, leftmost "Phasing Mode" tab 0 selects WersiVoice (OFF) or B�hm Phasing Rotor (ON)
- Firmware: improved PHR params
- DSP: Bugfix SysEx handling - important, otherwise MIDI communication with Editor will produce communication problems and timeout errors
- HX3.5 Editor: Added "Start DFU" DSP update by MIDI, added descriptions for WersiVoice/PHR, 8 Scanner Vibrato programs (Group Scan/Vib Progs)
08/16/2018 Firmware #5.091, HX3.5 Editor
- Bugfix: EEPROM init restauration after update or factory reset was faulty
- Changed INI scripts to properly setup System Inits
- Use new HX3.5 Editor to update firmware. Will always update EEPROM if firmware update by FTDI or MIDI is selected from drop-down menu.
Important: Please update firmware twice, otherwise Button Remaps may contain
garbage. With update by FTDI or MIDI using HX3.5 Editor, updating firmware
is sufficient. "Finalize" with HX3.5 Editor or by SD card INI script after update.
08/16/2018 Firmware #5.090, Scan Driver #14, HX3.5 Editor
- Bugfix: GM Voice save to Overall Preset
- Bugfix: External Rotary control switch (Extension Board)
- Bugfix: "randomly very low velocity sent" in Scan Driver
- GM voices minor bugfix
- HX3.5 Editor allows mapping of "extra" upper/lower/pedal voices #16..23 to any GM program number (see new
"DSP/GM Setup" group). Click "Save Params as Default" after editing to activate new mapping.
- Lowered "Relative Organ Volume" param 1491 (see DSP/GM Setup Group in HX3.5 Editor) to 64 for better match to GM voices
Note: Disable Param 1497 (Sync Voice Numbers) in "System Inits" to enable GM
Voice numbers saved in Overall Presets. From this FW and up, param 1497 will be disabled
by default. Do "Finalize" with HX3.5 Editor after update!
08/13/2018 Firmware #5.087, Scan Driver #12, DSP #01.02
- Mixture Drawbars will no longer sound on B3 and Combo Organ Models
- Phasing Rotor modulation enhanced
- Sostenuto pedal changed from MIDI CC $42 to $45 (69 dec.) due to NI B4 Perc CC conflict. Without this update, HX3 Drawbar
controller PERC ON will not work.
- DSP #01.02 will send CC $45 on Sostenuto pedal changes now
- MAG Organs only: Amp 122 volume will have a minimal amount
07/30/2018 Firmware 5#.085, HX3.5 Editor
- Firmware, Scan Driver and FPGA update via MIDI, MIDI over USB or FTDI cable possible (needs one-time update via SD card)
- HX3.5 Editor version 5.08 also works with MIDI or MIDI over USB connection (no driver required on Windows PCs)
- Bugfix on Drawbar Mixture setup
- Bugfix Overall Preset Handling
07/07/2018 Firmware #5.082, SD Card INI Scripts
- INI Script ReadLn bug fixed
- INI Scripts were corrupted (LF instead of CRLF)
07/02/2018 Firmware #5.080, FPGA #09072018
- "Common Preset Save" Bug fixed
- Lower default leakage, was way too high
- Issue with ENV_ENA Bits fixed, electronic gating was permanently on
- Various minor bugs fixed
01/09/2019 HX3.5 Editor 5.4051, DSP #01.14 (with GM voices) and #11.14 (no GM, but more reverb algorithms)
- Bugfix in USB library to prevent DSP stall using VMware Windows emulation on MacOS
- Extension Board Sostenuto input ("Main" jack) deleted, instead separate sustain pedal inputs for upper ("Bass" jack) and lower manual ("Main" jack)
- HX3.5 Editor: Bugfix Taperings update, wrong filename
12/12/2018 Firmware #5.405, DSP #01.13 (with GM voices) and #11.13 (no GM, but more reverb algorithms)
- DSP: Equalizer Bypass added
- Softer percussion for H100 Mode
- Preset16 Button "DoubleTap" feature (will recall GM voices, +16, blinking Preset16 LED) on standard organ installations may be turned off with param #1509
12/12/2018 Firmware #5.403 BETA, DSP #01.12 (with GM voices) and #11.12 (no GM, but more reverb algorithms)
- DSP: Fixed a bug that prevented SysEx block transfers
- Re-sorted DSP NRPNs
- Firmware: Generator mode on Parameter 1266 to retain compatibility with #5.3xx
- DSP: 3-Band Equalizer added with parametric mid control, available from
MenuPanel and HX3.5 Editor parameters "Volume Pots" resp. "Trim Pots". Equalizer
affects both Rotary simulation as well as Leslie (R) output on extension board.
Note: 3-Band EQ available for extended Licence only.
- Firmware: Generator Mode "knob" added. Will set waveset (sine distortion), key click
params, tonewheel count and note frequencies according to selected model.
- Firmware: Keying/Gating tabs (EG/H100) will not affect independant Generator Mode
- Firmware: Generator Mode "M3/M100" added
- Firmware #5.401: ADC scaling factor for MAG organs added (limited potentiometer range), should be at 120 for MAG organs and 100 for other
- Firmware #5.401: Fixed Equalizer parameter order
- Firmware #5.403: fixed Menu enables
Please update DSP to 01.12 or 11.12 first before attempting firmware or FPGA updates!
Click "Start DFU" in HX3.5 Editor's "Update/Finalize Panel" to start DFU Update.
Firmware #5.4 only works with DSP #01.12 resp. #11.12 and vice versa. See Update
Notes above!
Common firmware and EEPROM files for all products now contained
in HX3.5 Editor 5.4 ZIP from now on - no need to download UPDATE ZIPs
separately if not using SD Card for updates.
10/13/2018 Firmware 5.301, Scan Driver #17
- Scan Driver: Split will affect local keyboard only. Split will have no effect on MIDI input.
- Firmware: Bugfix, SysEx communication (i.e. HX3.5 Editor connection) fails on MIDI channels different from 1
Update Scan Driver if using MIDI input with masterkeyboards (will handle split
itself). If you want to retain previous split function (affects sound
generator), do not update Scan Driver or use #16 (enclosed).
09/19/2018 Firmware 5.300
- Firmware: Clavia Nord C1/C2 MIDI CC set #7
- Firmware: MIDI ProgramChange Send/Receive
- Firmware: MIDI Swell (Expression) Send, CC number same as in MIDI menu
- Firmware: Bank Select Send/Receive for Overall Presets
- Firmware: Faster integrator for MIDI Swell/Volume changes
- Firmware: Bugfixes 2nd Drawbar Set Select for DB9 MPX, Percussion Cancel
- HX3.5 Editor: Minor cosmetic changes, added DFU driver for Win XP in ZIP
Firmware 5.3 set to final status (no changes since last version 5.300 BETA).
Only "Firmware Update" (no EEPROM) necessary if updating from 5.105 and up.
KNOWN BUG: SysEx Communications will fail on MIDI Channels other than 1.
Therefore, HX3.5 Editor will no longer work with MIDI over USB connection.
Workaround: With HX3.5 MenuPanel, set MIDI Channel to 1 and store. In HX3.5
Editor, set parameter 1368 to 0 (= MIDI Channel 1).
09/19/2018 DSP Firmware HX35_5504-FW_0106.dfu, Firmware 5.202 BETA
- Firmware: Faster response to swell and volume changes via MIDI
- Firmware: Shortened menu list
- Firmware: Added Percussion/2nd Voice Level to menu
- Firmware: Added Envelope Drawbars for "EG Percussion" organ mode to menu
- DSP: Bugfix, Distorted "long release" GM sounds or with Damper/Sustain pedal on
- DSP: Bugfix, SysEx End recognition (GM sounds went off after SysEx transmission, i.e. HX3.5 Editor connected)
Only "Firmware Update" (no EEPROM) necessary if updating from 5.105 and up.
09/19/2018 Firmware #5.200, HX3.5 Editor #5.200
- HX3.5 Editor: Added function keys ESC, F1..F12 in Tab/DB Panel window for Preset/Voice recall #00..#12. USe SHIFT-ESC to SHIFT-F12 to read and refresh displayed parameters also. Use U/L/P/C keys to select Upper, Lower, Pedal or Common Presets.
- Firmware: Various small bug fixes, simplified Preset handling
- Firmware: New "Enable Preset Mask" parameter 1498 to enable/disable storing various param groups either to preset or to startup defaults (see parameter description in HX3.5 Editor)
09/19/2018 DSP Firmware HX35_5504-FW_0105.dfu and HX35_5504-FW_noGM_1105.dfu
- Added reverb to Extension board Leslie 11-pin and Output jacks
- Alternative DSP Reverb firmare noGM_11.05 available: No GM (Piano) voices, but more "large" Reverb Programs 0..9 instead of 0..3.
- List of reverb programs: 0: Off, 1: Short Room, 2: Room A, 3: Room B,
4: Small Hall A, 5: Small Hall B, 6: Large Hall A,
7: Large Hall B, 8: Short Plate, 9: Vocal Plate (Editor "Reverb Setup" Parameters 1145..1147)
DSP updates are included in the HX3.5 Editor ZIP.
See DSP Update Page for details.
09/20/2018 Scan Driver 5x.16 for Scan61-Inline and Scan16
- Added Scan Driver "scansr61.dat" for Scan61-Inline and Scan16 (single-contact keybeds)
- HX3.5 Editor: Added hint to run "config.ini" after firmware updates
- "config.ini" and "factory.ini" changed to sync Voices with Overall Presets, somewhat higher organ volume
For using the Scan61-Inline and Scan16 driver, just run "upd_sr61.ini" from
HX3.5 setup file menu (SD card) or update scan driver from HX3.5 Editor's
Update/Finalize window. "scansr61.dat" and "upd_sr61.ini" can be found in the
"UPDATE StdOrgan.ZIP".
09/19/2018 Firmware #5.105, HX3.5 Editor #5.105, Scan Driver 5x.16
- Firmware: Bugfix Preset/Live and Preset/Preset change
- Firmware: Will not forget presets and voices when updating
- Firmware: Bugfix "Split Mode not stored to Overall Presets"
- Scan Driver: Split mode handling improved
- Scan Driver: Bugfix non-working pedals on "Lower to Upper Split"
- HX3.5 Editor: Assignment Dropdown List Bugfix
- HX3.5 Editor: Changes for 16 KByte "preset.dat" file
For updates from #5.103 and below to #5.105 select "Firmware/EEPROM" and "Scan
Driver File" in HX3.5 Editor's Update/Finalize Window and Execute "config.ini"
from Editor. SD card updates will handle this automatically.
Hx3.5 will create a "preset.dat" file (button "Get & Save Preset Block" in
"Advanced" page) if connected by FTDI. This file contains all preset settings in
binary form. It may be uploaded by menu in Update/Finalize window or copied to
an SD card. If HX3.5 finds this file on a firmware update, it will be loaded
into preset memory.
Preset structure will not change in future, so this file may also be used as a backup.
09/12/2018 Firmware #5.104 BETA, HX3.5 Editor #5.104, Scan Driver 5x.15
- Known Bug: Preset/Preset change
- HX3.5 Editor: "Menu Enables" order fixed
- HX3.5 Editor: Added update entry "Firmware only" in Update/Finalize Window
- Firmware: Switching of H100/B2 Percussion fixed
- Firmware: "Sync Voices with Presets" enabled on UHL instruments
- Scan Driver: Bugfix MIDI channel assignment (was not able to receive on MIDI channels other than 1/2/3)
For updates to #5.104 select "Firmware/EEPROM" and "Scan Driver File" in HX3.5
Editor's Update/Finalize Window and Execute "config.ini" from Editor. SD card
updates will handle this automatically.
09/07/2018 Firmware #5.102, HX3.5 Editor #5.100, DSP #1.04
- HX3.5 Editor: New virtual organ panel with tabs and drawbars; should also work with older HX3.5 firmwares
- HX3.5 Editor: Will automatically start DreamDFU utility for DSP updates
- HX3.5 Editor: Added Backup support
- Firmware: Bugfix KeyB Duo MIDI CC set, Vibknob/MIDI to Panel16 translation, Perc menu display
- Firmware: Fail-save EEPROM file programming, unified firmware, "config.ini" support
- Firmware: Bugfix Percussion did not sound on preset to live change
- Firmware: Bugfix Rotary setting not memorized
- Firmware: Added Support for reading binary Preset and Voice setting blocks (OEM only)
- DSP: GM synth will no longer sound on channels out of organ channel range (1 to 3). Only update DSP if the GM synth should not sound on channels 4 to 16.
From firmware 5.1 and up, there is only one firmware common for all devices
(exception: MAG and UHL organs). Firmware is "personalized" to work on a
particular device by running a "config_xxx" INI script ("config_xxx.ini") from editor or by
using SD card after update is done.
If using an SD card for update, a script called "config.ini" is run
automatically after firmware update by "autorun.ini" (if present on card).
"config.ini" is simply a renamed "config_xxx.ini" file.
Please backup Licence Info before updating to #5.102! Unfortunately, older
firmwares had a data offset bug which did not retain licence information and
board defaults. When updating to #5.102, execute the "factory_xxx.ini" script
dedicated for your board application from HX3.5 Editor's Finalize window or
run "factory.ini" on SD card from HX3.5 Script Menu.
08/30/2018 Firmware #5.096, HX3.5 Editor #5.095
- Firmware: Bugfix "Bass Rotor won't stop completely"
- Firmware: Bugfix "KeyB (Duo) MIDI CC interpreter not working"
- HX3.5 Editor: Added Button "Create INI Script", creates INI setup file with all current parameters
- HX3.5 Editor: Added Button "Run INI Script", runs INI setup file from Editor similar to running from SD card
- Added INI Setup Scripts for manual full update via DisplayPanel menu (update.ini), forced EEPROM rewrite in case parameters are corrupted (eeprupd.ini),
and manual start DSP update in DFU mode, equivalent to HX3.5 Editor's "Start DFU" button (startdfu.ini)
08/25/2018 Firmware #5.093, HX3.5 Editor #5.09, DSP #01.03
- Firmware: Bugfix Update by USB MIDI
- Firmware: Added 8 separate Scanner Vibrato programs for 8 basic organ models, leftmost "Phasing Mode" tab 0 selects WersiVoice (OFF) or B�hm Phasing Rotor (ON)
- Firmware: improved PHR params
- DSP: Bugfix SysEx handling - important, otherwise MIDI communication with Editor will produce communication problems and timeout errors
- HX3.5 Editor: Added "Start DFU" DSP update by MIDI, added descriptions for WersiVoice/PHR, 8 Scanner Vibrato programs (Group Scan/Vib Progs)
08/16/2018 Firmware #5.091, HX3.5 Editor
- Bugfix: EEPROM init restauration after update or factory reset was faulty
- Changed INI scripts to properly setup System Inits
- Use new HX3.5 Editor to update firmware. Will always update EEPROM if firmware update by FTDI or MIDI is selected from drop-down menu.
Important: Please update firmware twice, otherwise Button Remaps may contain
garbage. With update by FTDI or MIDI using HX3.5 Editor, updating firmware
is sufficient. "Finalize" with HX3.5 Editor or by SD card INI script after update.
08/16/2018 Firmware #5.090, Scan Driver #14, HX3.5 Editor
- Bugfix: GM Voice save to Overall Preset
- Bugfix: External Rotary control switch (Extension Board)
- Bugfix: "randomly very low velocity sent" in Scan Driver
- GM voices minor bugfix
- HX3.5 Editor allows mapping of "extra" upper/lower/pedal voices #16..23 to any GM program number (see new
"DSP/GM Setup" group). Click "Save Params as Default" after editing to activate new mapping.
- Lowered "Relative Organ Volume" param 1491 (see DSP/GM Setup Group in HX3.5 Editor) to 64 for better match to GM voices
Note: Disable Param 1497 (Sync Voice Numbers) in "System Inits" to enable GM
Voice numbers saved in Overall Presets. From this FW and up, param 1497 will be disabled
by default. Do "Finalize" with HX3.5 Editor after update!
08/13/2018 Firmware #5.087, Scan Driver #12, DSP #01.02
- Mixture Drawbars will no longer sound on B3 and Combo Organ Models
- Phasing Rotor modulation enhanced
- Sostenuto pedal changed from MIDI CC $42 to $45 (69 dec.) due to NI B4 Perc CC conflict. Without this update, HX3 Drawbar
controller PERC ON will not work.
- DSP #01.02 will send CC $45 on Sostenuto pedal changes now
- MAG Organs only: Amp 122 volume will have a minimal amount
07/30/2018 Firmware 5#.085, HX3.5 Editor
- Firmware, Scan Driver and FPGA update via MIDI, MIDI over USB or FTDI cable possible (needs one-time update via SD card)
- HX3.5 Editor version 5.08 also works with MIDI or MIDI over USB connection (no driver required on Windows PCs)
- Bugfix on Drawbar Mixture setup
- Bugfix Overall Preset Handling
07/07/2018 Firmware #5.082, SD Card INI Scripts
- INI Script ReadLn bug fixed
- INI Scripts were corrupted (LF instead of CRLF)
07/02/2018 Firmware #5.080, FPGA #09072018
- "Common Preset Save" Bug fixed
- Lower default leakage, was way too high
- Issue with ENV_ENA Bits fixed, electronic gating was permanently on
- Various minor bugs fixed